VIP XD

Appendix en 63

 

 

8Appendix

8.1Troubleshooting

If you are unable to resolve a malfunction, please contact your supplier or systems integrator, or go directly to Bosch Security Systems Customer Service.

You can view a range of information about your unit version on the System Overview page (see Section 5.23 System Overview, page 51). Make a note of this information before contacting Customer Service. You can download an internal maintenance log from the unit on the Maintenance page if you wish to send it to Customer Service by e-mail (see

Section Maintenance log, page 50).

The following table is intended to help you identify the causes of malfunctions and correct them where possible.

Malfunction

Possible causes

Recommended solution

 

 

 

No connection between

Incorrect cable connections.

Check all cables, plugs,

the unit and terminal

 

contacts, terminals and

program.

 

connections.

 

 

 

 

The computer's serial interface

Check the other serial interface.

 

is not connected.

 

 

 

 

 

Interface parameters do not

If necessary select a different

 

match.

interface and make sure that the

 

 

computer's interface parameters

 

 

match those of the unit. Try the

 

 

following standard parameters:

 

 

19,200 baud, 8 data bits, no

 

 

parity, 1 stop bit. Next,

 

 

disconnect the unit from the

 

 

power supply and reconnect it

 

 

again after a few seconds.

 

 

 

No image on the monitor.

Monitor error.

Connect local camera or other

 

 

video source to the monitor and

 

 

check the monitor function.

 

 

 

 

Faulty cable connections.

Check all cables, plugs, contacts

 

 

and connections.

 

 

 

No connection

The unit's configuration.

Check all configuration

established, no image

 

parameters.

transmission.

 

 

Faulty installation.

Check all cables, plugs, contacts

 

 

and connections.

 

 

 

 

Wrong IP address.

Check the IP addresses

 

 

(terminal program).

 

 

 

 

Faulty data transmission within

Check the data transmission

 

the LAN.

with ping.

 

 

 

 

The maximum number of

Wait until there is a free

 

connections has been reached.

connection and then call the

 

 

sender again.

 

 

 

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Page 63
Image 63
Bosch Appliances VIP, XD manual 8Appendix, 1Troubleshooting, Malfunction Possible causes Recommended solution