42 en Configuration Using a Web Browser

VIP XD

 

 

Operating mode

Select an operating mode for the relay.

For example, if you want an alarm-activated lamp to stay on after the alarm ends, select Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select

10 s.

Relay follows

If required, select a specific event that will trigger the relay. The following events are possible triggers:

Off

Relay is not triggered by events

Connection

Trigger whenever a connection is made

Local input 1

Trigger by external alarm input 1

Remote input 1

Trigger by remote station's switching contact 1 (only if a connection exists)

Relay name

You can assign a name for the relay here. The name is shown on the button next to Trigger relay.

Trigger relay

Click the button to trigger the relay manually (for testing or to operate a door opener, for example).

DOC V4.0 2009.06

Installation and Operating Manual

Bosch Security Systems

Page 42