64 en AppendixVIP XD

Malfunction

Possible causes

Recommended solution

 

 

 

No audio transmission to

Hardware fault.

Check that all connected audio

remote station.

 

units are operating correctly.

 

 

 

 

Faulty cable connections.

Check all cables, plugs, contacts

 

 

and connections.

 

 

 

 

Incorrect configuration.

Check the audio parameters on

 

 

the Audio configuration page.

 

 

 

 

The audio voice connection is

Wait until the connection is free

 

already in use by another

and then call the sender again.

 

receiver.

 

 

 

 

The unit does not report

Alarm source is not selected.

Select possible alarm sources on

an alarm.

 

the Alarm Inputs configuration

 

 

page.

 

 

 

 

No alarm response specified.

Specify the desired alarm

 

 

response on the Alarm

 

 

Connections configuration page,

 

 

change the IP address if

 

 

necessary.

 

 

 

Control of cameras or

The cable connection between

Check all cable connections and

other units is not

the serial interface and the

ensure all plugs are properly

possible.

connected unit is not correct.

fitted.

 

 

 

 

The interface parameters do not

Make sure that the settings of all

 

match those of the other unit

units involved are compatible.

 

connected.

 

 

 

 

The unit is not

Power failure during

Have the unit checked by

operational after a

programming by firmware file.

Customer Service and replace if

firmware upload.

 

necessary.

 

 

 

 

Incorrect firmware file.

Enter the IP address of the unit

 

 

followed by /main.htm in your

 

 

Web browser and repeat the

 

 

upload.

 

 

 

Placeholders with a red

Sun JVM is not installed on the

Install Sun JVM from the

cross are displayed

computer or is not enabled.

product CD.

instead of the ActiveX

 

 

components.

 

 

 

 

 

Web browser contains

Active proxy server in network.

Create a rule in the local

empty fields.

 

computer's proxy settings to

 

 

exclude local IP addresses.

 

 

 

If a sender is connected

Auto-connect configured.

Deactivate auto-connect.

to the receiver, the first

 

 

connection remains.

 

 

 

 

 