Bosch Appliances XD Serial Interface, Terminal Block, Pin Assignment, 17 COM1, page, RS-232 mode

Models: VIP

1 80
Download 80 pages 8.55 Kb
Page 66
Image 66
Serial Interface

66 en AppendixVIP XD

8.5

Serial Interface

 

Options for using the serial interface include transferring transparent data, controlling

 

connected units or operating the unit with a terminal program.

 

The serial interface supports the RS-232/RS-422/RS-485 transmission standards. The mode

 

used depends on the current configuration (see Section 5.17 COM1, page 43). Connection is

 

via the terminal block.

8.6

Terminal Block

 

The terminal block has several contacts for:

 

4 alarm inputs

 

1 relay output

 

Serial data transmission

Pin Assignment

The pin assignment of the serial interface depends on the interface mode used (see

Section 5.17 COM1, page 43).

Contact

RS-232 mode

RS-422 mode

RS-485 mode

 

 

 

 

CTS

CTS (clear to send)

RxD- (receive data minus)

Data-

 

 

 

 

RTS

RTS (ready to send)

TxD- (transmit data minus)

 

 

 

 

 

RXD

RxD (receive data)

RxD+ (receive data plus)

Data+

 

 

 

 

TXD

TxD (transmit data)

TxD+ (transmit data plus)

 

 

 

 

 

GND

GND (ground)

 

 

 

 

Contact

Function

 

 

IN1

Input alarm 1

 

 

IN2

Input alarm 2

 

 

IN3

Input alarm 3

 

 

IN4

Input alarm 4

 

 

GND

Ground

 

 

R

Relay Output

 

 

+

12 to 24 V DC (power supply)

 

 

Ground

 

 

Connect each alarm input to a ground contact (GND) when connecting alarm inputs.

DOC V4.0 2009.06

Installation and Operating Manual

Bosch Security Systems

Page 66
Image 66
Bosch Appliances XD Serial Interface, Terminal Block, Pin Assignment, 17 COM1, page, RS-232 mode, RS-422 mode, RS-485 mode