LEDs

VIP XDAppendix en 65

8.2

LEDs

 

The VIP XD network video server has a number of LEDs on its rear panel that show the

 

operating status and can give indications of possible malfunctions:

 

Operating Status LED

Does not light up:

VIP XD is switched off.

Lights up green:

VIP XD is switched on.

Flashes green:

The VIP XD is being accessed.

Flashes red:

Startup in progress.

Lights up red:

VIP XD is faulty, for example following failed firmware

 

upload.

LED L

 

Does not light up:

No network connection.

Lights up green:

Network connection established.

LED T

 

Flashes orange:

Data being transmitted over the network.

8.3Processor Load

If the VIP XD is accessed via the Web browser, you will see the processor load indicator in the top left of the window next to the manufacturer's logo.

 

Moving the mouse cursor over the graphic indicator displays the status of the processor

 

together with the numerical values. This information may help you with troubleshooting or

 

fine tuning the unit.

8.4

Network Connection

You can display information about the network connection. To do this, move the cursor over the i icon.

Link

Ethernet link type

UL

Uplink, speed of the outgoing data traffic

DL

Downlink, speed of the incoming data traffic