Line In / Microphone (MIC)

34 en Configuration Using a Web Browser

VIP XD

 

 

Line In / Microphone (MIC)

You can set the audio signal gain for the line and microphone input. Make sure that the display does not go beyond the green zone during modulation.

Line Out/Speaker (SPK)

You can set the gain of the line and loudspeaker output. Make sure that the display does not go beyond the green zone during modulation.

Selection

Click one of the option boxes and then click Set to display the level of the respective audio input for orientation and to set the gain.

5.11

Alarm Connections

You can select how the VIP XD responds to an alarm. In the event of an alarm, the unit can automatically connect to a pre-defined IP address. You can enter up to ten IP addresses to which the VIP XD will connect in sequence in the event of an alarm, until a connection is made.

Connect on alarm

Select On so that the VIP XD automatically connects to a predefined IP address in the event of an alarm.

By setting Follows input 1, the VIP XD automatically connects to a remote station and holds the connection as long as an alarm exists on alarm input 1. This option can also be used to connect two units (sender and receiver) via a switch connected to the VIP XD. You do not need a computer to make the connection in this case.

NOTICE!

i In the default setting, Stream 2 is transmitted for automatic connections. Bear this fact in mind when assigning the profile to the corresponding sender.