TTW1 Universal Service

Replacement Blower

MITW -10 Series

Step 12. Find the rubber vent adapter kit, P/N 239-46263-00, provided with the blower kit. Install the 2” vent adapter on the exhaust side of the universal blower. Discard the vent terminal included with the vent adapter kit.

Note: In order to prevent condensate from draining back into the blower (vertical or horizontal runs), an optional condensate kit is available as a service part (Condensate kit, P/N 239-45875-00).

Step 13. If it has not already been done, remove the old vent adapter from the existing vent pipe.

Step 14. If necessary, re-route the vent pipe such that it can be properly seated in the top portion of the vent adapter.

Step 15. Be sure that both clamps on the vent adapter are firmly tightened, securing the blower, vent adapter, and vent pipe together.

Be sure that vent pipe is properly seated in the top side of vent adapter.

Rubber vent

adapter

Adequately tighten both

clamps on the vent adapter.

Step 16. Double-check all vent connections.

Step 17. Restore electrical power to the water heater.

Plug power cord back into outlet.

Warning:

Check all safety devices to make sure they

 

are working properly. Improper water heater

 

operation could occur if these devices are not

 

functioning properly.