TTW1 Universal Service
Replacement Blower
M1TW Series
Step 12. Find the rubber vent adapter kit, P/N
kit. Install the 2” vent adapter on the exhaust side of the universal blower.
Discard the vent terminal included with
the vent adapter kit.
Be sure that vent pipe is properly
seated in the top side of vent adapter.
Note: In order to prevent condensate from draining |
| Rubber vent adapter | ||
back into the blower (vertical or horizontal runs), |
| |||
an optional condensate kit is available as a |
|
| ||
service part (Condensate kit, P/N |
| Adequately tighten both | ||
|
|
| ||
Step 13. | If the new adapter is used, remove the old | |||
clamps on the vent adapter. | ||||
| vent adapter from the existing vent pipe. |
|
Step 14. Be sure that both clamps on the vent adapter are firmly tightened, securing the blower, vent adapter, and vent pipe together.
|
| Plug power cord |
Step 15. | back into outlet. | |
Step 16. | Restore electrical power to the water |
|
| heater. |
|
Turn switch on gas
valve to “On” position.
Step 17. On the water heater's gas control, turn the
power switch to the “On” position.
Warning: | Check all safety devices to make sure they |
| are working properly. Improper water heater |
| operation could occur if these devices are not |
| functioning properly. |
Page 26