TTW1 Universal Service

Replacement Blower

MITW -10 Series

Note: This set of instructions is for the following model numbers: MITW40L*LN10, MITW40L*CX10, MITW50L*LN10, and MITW50L*CX10.

Note: The following parts are required to convert the model numbers shown above: Template, Flue Restrictor, Screws, Wire Harness MITW-10Series, Universal Blower, Wire Nuts, and 2" Exhaust Adapter / Vent Terminal Kit. Please refer to the Kit Components page (Page 3) for a picture of each item.

Step 1. Unplug water heater from wall outlet.

Remove power cord from outlet.

Unplug blower harness from

jacket head receptacle.

Step 2. Detach blower wire harness from receptacle located in the jacket head.

Unscrew both clamps that

hold the adapter to the blower and vent pipe.

Step 3. Disconnect the vent pipe and adapter that are connected to the outlet of the blower.