Bradford-White Corp MITW -12 / -15, MITW -10 manual TTW1 Universal Service Replacement Blower

Models: MITW -10 MITW -12 / -15

1 27
Download 27 pages 16.7 Kb
Page 17
Image 17

TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Step 12.

a.) Position the junction box, P/N 239-47196-00, on top of the water heater, in front of the blower, and on the side nearest the T&P valve.

b.) Place the transformer, P/N 265-44072-01, inside the junction box such that there is sufficient room between its (4) posts and the sidewalls of the junction box. Determine the side to remove a knock-out. Remove the transformer from the junction box.

Place junction box

on top of water

heater and

transformer in box.

Blower

harness

receptacles

Leave room in corner

closest to blower harness

receptacles to attach

terminals to transformer.

Remove ¾"

knockout.

c.) On a side opposite the transformer's posts, remove (1) knock-out ¾" in size. Then, place the junction box back on the water heater and the transformer back into the box.

d.) Mark the location of the mounting holes of the transformer onto the junction box.

e.) Remove the transformer from the junction box.

f.) Drill (2) 1/8” diameter holes in the locations that were marked in Step 12d. Be sure that the pilot holes are through the junction box and jacket head.

Junction box

Transformer

Mark the location of transformer in box.

Page 17

Page 17
Image 17
Bradford-White Corp MITW -12 / -15, MITW -10 manual TTW1 Universal Service Replacement Blower