TTW1 Universal Service

Replacement Blower

M1TW Series

Step 4. Disconnect the vent pipe and adapter that are connected to the outlet of the blower.

Unscrew both clamps that

hold the adapter to the blower and vent pipe.

Unscrew (3) screws that hold

blower to the jacket head.

Step 5.

Remove the screws, qty. (3), that secure

 

the blower to the jacket head.

Step 6.

Remove blower from the top of the water

 

heater. Remove any loose debris and

 

tools from the top of the water heater.

 

 

Warning:

For normal altitude applications (2000 ft. & below), proceed to Step 8.

 

Otherwise, for high altitude applications (2001 ft. & above), continue with

 

Step 7.

Step 7.

Instructions to replace universal blower

 

pressure switch:

 

 

 

Warning:

Only replace the pressure switch if the

 

 

water heater is being used in high altitude

 

 

application. Failure to replace universal

 

 

blower pressure switch will result in

 

 

improper water heater operation.

 

 

 

 

 

 

a.) Unscrew the (3) Philips head screws

 

on the blower access cover and

 

remove the cover. Keep the cover and

 

screws for future use.

 

 

Warning:

Do NOT remove Torx head screws from

 

 

 

universal blower.

 

 

 

 

 

Blower access cover

(covers access compartment)

Loosen all (3) screws

holding cover on.

Page 22

Page 22
Image 22
Bradford-White Corp MITW -10, MITW -12 / -15 manual TTW1 Universal Service Replacement Blower