TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Note: This set of instructions is for the following model numbers: MITW40L*EN12,

MITW40L*BN12, MITW40L*CX12, MITW50L*EN12, MITW50L*BN12,MITW50L*CX12, MITW40L*EN15, MITW40L*BN15, MITW40L*CX15, MITW50L*EN15, MITW50L*BN15, and MITW50L*CX15.

Note: The following parts are required to convert the model numbers shown above: Template, Flue Restrictor, Screws, Wire Harness MITW-12/15Series, Universal Blower, Transformer, Junction Box & its Cover, Wire Nuts, and 2" Exhaust Adapter / Vent Terminal Kit. Please refer to the Kit Components page (Page 3) for a picture of each item.

Step 1. On the water heater’s gas control, turn the power switch to the “Off” position.

Turn switch on gas

valve to “Off” position.

Step 2. Unplug the water heater from wall outlet.

Remove power

cord from

outlet.

Unscrew both clamps that

hold the adapter to the blower and vent pipe.

Step 3. Disconnect the vent pipe and adapter that are connected to the outlet of the blower.

Page 12

Page 12
Image 12
Bradford-White Corp MITW -10, MITW -12 / -15 manual Unplug the water heater from wall outlet