Bradford-White Corp MITW -10 manual Place template on top of water heater in correct orientation

Models: MITW -10 MITW -12 / -15

1 27
Download 27 pages 16.7 Kb
Page 14
Image 14

TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Slip the template over the water connections. It is not necessary to remove the pipes connected to the water heater’s inlet and outlet.

Step 7.

b.) Place the template on top of the water heater, being sure to have the arrows point towards the front of the water heater, which is the side where the drain and gas valve are located. Tape the template to the top of the water heater to hold it in place.

Place template on top of water heater in correct orientation.

c.) At each of the (3) “Drill Here” locations on the template, drill a 1/8” diameter hole through the template and the jacket head. Remove the template from the top of the water heater.

Drill (3) locations on top of water heater, where “Drill Here” is noted on the template.

Warning:

Failure to install flue restrictor will result in

 

 

improper water heater operation.

 

 

 

 

Step 8.

Install the flue restrictor, P/N

 

239-47191-00, firmly on the flue. It may

 

be necessary to lightly tap down the flue

 

restrictor. Be sure to tap it evenly and

 

straight down. Wire brush the top of the

 

water heater if rust or corrosion exists.

 

 

Warning:

Do NOT remove Torx head screws from

 

 

universal blower.

 

 

 

 

Step 9.

Instructions to remove power cord from

 

new universal blower:

 

a.) Unscrew the (3) Philips head screws

 

on the blower access cover and

 

remove the cover. Keep the cover and

 

screws for future use.

 

Blower access cover

 

(covers access compartment)

Drill

Place flue

restrictor on flue.

Loosen all (3) screws

holding cover on.

Power inlet

connector

Page 14

Page 14
Image 14
Bradford-White Corp MITW -10, MITW -12 / -15 manual Place template on top of water heater in correct orientation