TTW1 Universal Service

Replacement Blower

MITW -10 Series

Step 4.

Remove the screws, qty. (4), that secure

Unscrew (4) screws that hold

blower to the jacket head.

 

the blower to the jacket head.

 

Step 5.

Remove blower from the top of the water

 

 

heater. Remove any loose debris and

 

 

tools from the top of the water heater,

 

 

including any portion of the blower gasket

 

 

that still exists.

 

Warning:

Failure to locate the blower correctly will

 

 

result in improper water heater operation.

 

 

 

 

Step 6.

Create the new mounting hole locations

 

for the new universal replacement blower.

 

Use template supplied with manual.

 

a.) On the template, P/N 238-47197-00,

 

the (3) circular sections for the water

 

connections and flue have already

 

been removed. Also, the dotted lines

 

from the side of the paper are

 

perforated for easy tearing.

 

Slip the template over the water connections. It

 

is not necessary to remove the pipes connected

 

to the water heater’s inlet and outlet.

 

b.) Place the template on top of the water

 

heater, being sure to have the arrows

 

point towards the front of the water

 

heater, which is the side where the

 

drain and gas valve are located. Tape

 

the template to the top of the water

 

heater to hold it in place.

The (3) circular sections on template have been pre-cut and removed.

Tear paper along dotted lines where perforation exists, or cut with scissors.

Place template on top of water heater in correct orientation.

c.) At each of the (3) “Drill Here” locations

 

on the template, drill a 1/8” diameter

 

hole through the template and the

Drill

jacket head. Remove the template

from the top of the water heater.

 

Drill (3) locations on top of water heater, where “Drill Here” is noted on the template.

Page 7

Page 7
Image 7
Bradford-White Corp MITW -12 / -15, MITW -10 manual Step Remove the screws, qty , that secure