TTW1 Universal Service

Replacement Blower

M1TW Series

Note: This set of instructions is for the following model numbers:

M1TW40S*BN, M1TW40S*CX, M1TW50S*BN,

M1TW50S*CX, M1TW40S*FBN, M1TW40S*FCX,

M1TW50S*FBN, M1TW50S*FCX, M1TW60T*FBN, and

M1TW60T*FCX.

Note: The following parts are required to convert the model numbers shown above: Screws, Universal Blower, Dilution Air Orifice, Pressure Switch (-0.70" wc, for high altitude only), and 2" Exhaust Adapter / Vent Terminal Kit. Please refer to the Kit Components page (Page 3) for a picture of each item.

Step 1. On the water heater’s gas control, turn the power switch to the “Off” position.

Turn switch on gas valve

to “Off” position.

Step 2. Unplug water heater from wall outlet.

Remove power cord from outlet.

Unplug blower harness cord sets from blower housing receptacles.

Step 3. Disconnect blower cord sets from receptacles located in the blower housing.