TTW1 Universal Service
Replacement Blower
MITW -12 / -15 Series
Step 4. Remove the screws, qty. (3), that secure the blower to the jacket head.
Unscrew (3) screws that hold
blower to the jacket head.
Blower junction box
Step 5. Disconnect blower wire harness from receptacle, located in the jacket head under the blower junction box. The white connector must be pinched to remove.
Unplug blower harness from jacket head receptacle by pinching the connector.
Step 6. | Remove the blower from the top of the | |
| water heater. Remove any loose debris | |
| and tools from the top of the water heater. | |
|
| |
Warning: | Failure to locate the blower correctly will |
|
| result in improper water heater operation. |
|
|
|
|
Step 7. | Create the new mounting hole locations | |
| for the new universal replacement blower. | |
| Use template supplied with manual. | |
| a.) On the template, P/N | |
| the (3) circular sections for the water | |
| connections and flue have already | |
| been removed. Also, the dotted lines | |
| from the side of the paper are | |
| perforated for easy tearing. |
The (3) circular sections on template have been
Tear paper along dotted lines where perforation exists, or cut with scissors.
Page 13