Chapter 4: Troubleshooting

Table 4-1 LANVIEW LEDs

LED

Color

Description

Error Condition

Recommended Action

 

 

 

 

 

 

 

 

 

 

 

CPU

Off

Power off.

Turn power on.

 

 

 

 

 

Red

Blinking. SDRAM or

Contact Cabletron Systems

 

 

LDRAM failure.

Technical Support.

 

 

 

 

 

Yellow

Blinking. No

Contact Cabletron Systems

 

 

communications with

Technical Support for

 

 

switch processor.

assistance.

 

 

 

 

 

Green

Blinking. Board OK.

No action.

 

 

 

 

 

Yellow

Blink 1/2 sec. green

Verify LED blinks green only

 

and

and 1/2 sec. yellow.

after approx. 45 seconds.

 

Green

Booting. Performing

Otherwise, press the RESET

 

 

BOOTP, TFTP, or

button.

 

 

loading from FLASH.

 

 

 

 

 

 

Yellow

Testing. Board

Verify LED blinks green after

 

 

performing memory

approx. 180 seconds.

 

 

test.

Otherwise, press the RESET

 

 

 

button.

 

 

 

 

Transmit

Off

Port enabled, no

Should flash green every 2

 

 

activity.

seconds indicating BPDUs

 

 

 

being sent if Spanning Tree

 

 

 

Algorithm is active.

 

 

 

 

 

Green

Flashing. Indicates

No error.

 

 

activity or enabled port.

 

 

 

Note that the flashing is

 

 

 

pulsed-stretched for

 

 

 

easy viewing and does

 

 

 

not accurately

 

 

 

represent the rate of

 

 

 

traffic.

 

 

 

 

 

 

Yellow

Blinking. Port in

May be disabled due to

 

 

standby.

Spanning Tree Algorithm.

 

 

 

 

 

Red

Flashing to constantly

If on constantly indicates a

 

 

on. Indicates collision

problem. Contact Cabletron

 

 

rate.

Systems Technical Support for

 

 

 

assistance.

 

 

 

 

 

Red

Solid. Port disabled.

Contact Cabletron Systems

 

 

 

Technical Support for

 

 

 

assistance.

 

 

 

 

4-2

ESX-1320/ESX-1380 Installation Guide

Page 42
Image 42
Cabletron Systems ESX-1320 manual Troubleshooting