Cabletron Systems ESXMIM-F2 manual Cable Configuration for the Management Terminal

Models: ESXMIM-F2 ESXMIM

1 86
Download 86 pages 26.87 Kb
Page 23
Image 23

Management Terminal Setup Requirements

2.2.1Cable Configuration for the Management Terminal

This section outlines the proper cable configurations to connect a management terminal to the ESXMIM.

You need an adapter kit containing the following items to connect a terminal to the ESXMIM:

One RS232 cable

One VT series adapter

One device cable

The adapter you use depends on whether you connect a VT320 or VT 220 terminal or a PC emulating a VT320 or VT220 to an ESXMIM COM port. Read the information included with the adapter kit to make sure that you are using the correct adapter.

To configure the cables, perform the following steps:

1.Plug a straight-through twisted pair cable (e.g., an RS232 cable) into the ESXMIM’s COM port.

2.Plug the other end of the RS232 cable into the adapter.

3.Connect the adapter into the device cable and plug the other end of the device cable into the terminal.

4.Power on the terminal. Access to Local Management is automatic. However, because of auto-baud detection, you may need to press

ENTER.

ESXMIM/ESXMIM-F2 Local Management Guide