CH Tech EM405D Specifications, Maximum Ratings, Characteristics, Parameter, Condition, Units

Models: EM405D

1 48
Download 48 pages 8.75 Kb
Page 8
Image 8

1.2.2 Specifications

MAXIMUM RATINGS

Parameter

Condition

Rating

Units

Operating Temperature

 

0 to +60

°C

Non-Operating Temperature

 

-40 to +75

°C

Humidity

non-condensing

5 to 95

%

Input DC Power Level

 

12.6

V max.

Power Consumption

Support for two M-modules at full power

30

Watts

External Trigger Input

Power Off

± 40

V

 

Power On

± 36

V

CHARACTERISTICS

 

 

 

Limit

 

 

Parameter

Conditions

Min

Typ.

Max

Units

Data Transfers

 

 

 

 

 

Throughput

Wired Ethernet – block read 1, 3

 

 

90K

bytes/sec

 

Wired Ethernet – block write 2, 3

 

 

40K

bytes/sec

 

Wireless Ethernet – block read 1, 3

 

 

23K

bytes/sec

 

Wireless Ethernet – block write 2, 3

 

 

14K

bytes/sec

Input Power Supply

 

 

 

 

 

Level

DC

11.4

12.0

12.6

V

Current

for full M-module support

2.5

 

 

A

Ripple/noise

20MHz bandwidth

-1.5

 

+1.5

%

Power Consumption

 

 

 

 

 

Carrier

-0001 wired Ethernet

460

470

550

mA

 

-0002 wireless Ethernet

500

510

590

mA

M-modules (each position)

+5V

 

 

1.0

A

 

+12V

 

 

200

mA

 

-12V

 

 

200

mA

Triggers

 

 

 

 

 

Output Level

into a high impedance load

3.8

5.0

5.4

V

Output Impedance

 

 

50

 

Ω

 

 

 

 

 

 

Input Level

TLVL = 0 4

 

2.5

 

V

 

TLVL = 1

 

1.4

 

V

Input Impedance

TIMP = 0 4

100K

 

 

Ω

 

TIMP = 1

 

50

 

Ω

 

 

 

 

 

 

External Trigger Delay

External connector to M-module

 

30

40

ns

 

M-module to external connector

 

30

40

ns

 

M-module to M-module

 

30

40

ns

Cooling

 

 

 

 

 

Temperature Rise

 

 

 

20

°C

Temperature Accuracy

 

-2

 

+2

°C

Notes:

1.12-24ms latency occurs on each command issued. The effect of this latency is reduced by transferring large amounts of data with a single block read command. Maximum read throughput is achieved by reading >64K bytes of data from a FIFO type register on an M-module using the Block Read command. Host software may vary and can limit the maximum throughput.

2.The maximum number of bytes that can be written in a single block write command is 1024.

3.Ethernet is a non-deterministic communications interface. Realized throughput may be significantly degraded by network activity or other factors that may affect network performance.

4.TLVL and TIMP refer to register bits in the Reset & Trigger Control register. Refer to section 4.3.5.

2

Page 8
Image 8
CH Tech EM405D user manual Specifications, Maximum Ratings, Characteristics, Parameter, Units, Conditions