4.3.5 EM405D Configuration/Status Registers

The EM405D contains a set of registers that are used to identify the carrier, configure the carrier, and retrieve status from the carrier. These registers are independent of the M-modules residing on the board. Table III summarizes the register map. Bit level details of each register can be found in Figure 7. These registers are accessed using the Read Data and Write Data commands with the module field of the command set to ‘0’.

 

Table III. Register Summary

 

 

 

Offset

 

Register

0x00

 

Reset Error & Manufacturer Identification

0x02

 

Device Identification

0x04

 

Hardware Version

0x06

 

Firmware Version

0x08

 

Reset & Trigger Control

0x0A

 

Fan Control & Temperature Status

Reset Error & Manufacturer Identification (0x00): A read of this register will return the 12-bit manufacturer ID value of the EM405D and the reset error bit. The manufacturer ID field is read- only. Writing a ‘1’ to the reset error bit will clear the error condition. Refer to section 4.3.1 for details on error handling.

Device Identification (0x02): This read-only register returns the device ID value of the EM405D and a bit indicating whether the EM405D is a wired or wireless (Wi-Fi) version.

Hardware Version (0x04): This read-only register returns the hardware version number of the EM405D being accessed.

Firmware Version (0x06): This read-only register returns the firmware version number of the EM405D being accessed.

Reset & Trigger Control (0x08): This read/write register can be used to reset the M-modules residing on the EM405D and to control the triggers. An independent reset bit is available for each module as well as numerous bits that allow the user to configure the external trigger lines and to map each M-module trigger.

Fan Control & Temperature Status (0x0A): A read of this register will return a value representative of the current temperature inside the EM405D casing and will return the current setting of the fan control bit. The temperature field of this register is read only. By writing to the fan control bit, the user can select whether the fan is set to full-on or variable speed.