1.3 Electrical
The EM405D only requires a +12V DC power input. The +12V input is internally converted to the +3.3V power required by the carrier and the +5V, +12V, and 
1.4 Mechanical
The EM405D is contained in a metal chassis with an outside dimension of 5.6 inches wide by 8.5 inches deep by 1.5 inches high. A variable speed fan provides forced air for cooling the M- modules. The unit weighs approximately 1.7 lbs with no 
1.5 Environmental
The environmental specifications of the module are:
Operating Temperature:  | 0°C to +60°C*  | 
Storage Temperature:  | |
Humidity:  | <95% without condensation  | 
*The forced air cooling is designed to allow a maximum 20°C temperature rise for installed M- modules. In other words, with two 
Installed M/MAs may differ in environmental specification. Refer to each individual M/MA’s documentation for information.
1.6 Bus Compliance
The module complies with the ANSI/VITA 
Addressing:  | A08 only (extended addressing not supported)  | 
Data:  | D16 only  | 
Interrupts:  | not supported  | 
DMA: | not supported  | 
Triggers:  | Trig A and Trig B Input/Output  | 
Manufacturer ID:  | 0FC116  | 
Model Number:  | 0FDB16  | 
3