Manuals
/
CH Tech
/
Computer Equipment
/
Network Router
CH Tech
EM405D user manual U S E R S M A N U A L E T H E R N E T M - M O D U L E C A R R I E R
Models:
EM405D
1
1
48
48
Download
48 pages
8.75 Kb
1
2
3
4
5
6
7
8
<
>
Specs
Characteristics
Install
M/MA Configuration Diagram
Configuring The Ethernet Interface
Appendix B - Wired Ethernet Default Settings
Reset Error & Manufacturer Identification
Table I. Command Summary
The default subnet mask is 4.2.3 Gateway
IP Settings
Page 1
Image 1
U S E R ' S M A N U A L
E T H E R N E T
M - M O D U L E
C A R R I E R
M O D E L
E M 4 0 5 D
Manual Part No: 11028854
Page 2
Page 1
Image 1
Page 2
Contents
M O D E L E M 4 0 5 D
U S E R S M A N U A L E T H E R N E T M - M O D U L E C A R R I E R
Manual Part No
Copyright 2004 by C&H Technologies, Inc
COPYRIGHT
DOCUMENT REVISION NOTICE
INTRODUCTION
INSTALLATION
TABLE OF CONTENTS
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTION
APPENDIX B - WIRED ETHERNET DEFAULT SETTINGS
APPENDIX A - CONNECTORS
APPENDIX C - WIRELESS ETHERNET WI-FI DEFAULT SETTINGS
LIST OF FIGURES
1.0 GENERAL DESCRIPTION
1.2 FEATURES AND SPECIFICATIONS 1.2.1 Key Features
Figure 1. EM405D Ethernet M-Module Carrier 1.1 PURPOSE OF EQUIPMENT
CHARACTERISTICS
1.2.2 Specifications
MAXIMUM RATINGS
Parameter
1.4 Mechanical
1.3 Electrical
1.5 Environmental
1.6 Bus Compliance
IEEE-802.11b, Wireless Ethernet Standard
1.7 APPLICABLE DOCUMENTS
IEEE-802.3 ANSI 8802.3, Ethernet Network Standard
2.2 HANDLING PRECAUTIONS
2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION
2.3 INSTALLATION OF M-MODULES
Figure 2. M-module Installation
MODULE B
Figure 3. M/MA Configuration Diagram
MODULE A
3.0 FUNCTIONAL DESCRIPTION 3.1 GENERAL
Figure 4. Functional Block Diagram 3.1.1 Embedded Controller
3.1.2 Ethernet Interface
ETHERNET
3.1.3 M-module Interface
3.1.4 Power Conversion
3.2 REAR PANEL
Figure 5. Rear Panel
Figure 6. Front Panel
3.3 FRONT PANEL
EM405D ETHERNET M-MODULE CARRIER
Page
4.0 OPERATING INSTRUCTIONS 4.1 GENERAL
4.2 CONFIGURING THE ETHERNET INTERFACE
4.2.1 IP Address
The default gateway address is 4.2.4 Port Numbers
The default subnet mask is 4.2.3 Gateway
The default port number for standard module access is
4.2.5 Wireless Settings
The default settings are WEP disabled and WPA disabled
The default setting is Auto-Scan
4.2.6 Performing the Configuration - Wired Ethernet
telnet x.x.x.x
4.2.7 Performing the Configuration - Wireless Ethernet Wi-Fi
4.2.7.1 Wed-based Configuration
4.3.1 Error Handling
Table I. Command Summary
4.3 COMMUNICATING WITH THE CARRIER AND M-MODULES
Table II. Status Code SC
Successful 0x00 The command completed successfully without error
4.3.3 Read Data command
4.3.2 Write Data command
4.3.4 Block Access
4.3.4.1 Block Write command
4.3.4.2 Block Read command
Table III. Register Summary
4.3.5 EM405D Configuration/Status Registers
Offset
Register
Device Identification
Reset Error & Manufacturer Identification
Hardware Version
Firmware Version
Fan Control & Temperature Status
Reset & Trigger Control
Figure 7. EM405D Registers continued
Enclosure Temperature C = TEMP - 281
4.4 CONTROLLING THE TRIGGERS
C = TEMP - 281
4.5 FAN AND TEMPERATURE CONTROL
Page
PIN DESCRIPTION 1 +12V INPUT 2 +12V INPUT 3 +12V INPUT 4 TRIGGER OUT
Figure A-1. 9-Pin DSUB Connector
5 TRIGGER IN 6 GND 7 GND 8 GND 9 GND
Page
Table B-1. Ethernet Interface Default Settings
Table B-1. Ethernet Interface Default Settings. continued
OEM Configurable Pins
Table B-1. Ethernet Interface Default Settings. continued
Email Notification
blank
Page
IP Settings
Table C-1. Wireless Ethernet Configuration Default Settings
Wireless LAN Settings
Wireless Security Settings
Port Profile Settings
Advanced Network Settings
TCP Server Settings
TCP Client Settings
blank
blank
blank
Page
N O T E S
Page
READERS COMMENT FORM
INSTRUCTIONS