Manuals
/
CH Tech
/
Computer Equipment
/
Network Router
CH Tech
EM405D user manual
Models:
EM405D
1
44
48
48
Download
48 pages
8.75 Kb
41
42
43
44
45
46
47
48
<
>
Specifications
Install
Reset & Trigger Control
Table I. Command Summary
Wireless Settings
Power Conversion
Network Services Settings
Block Access
Appendix A - Connectors
Page 44
Image 44
C-4
Page 43
Page 45
Page 44
Image 44
Page 43
Page 45
Contents
Manual Part No
U S E R S M A N U A L E T H E R N E T M - M O D U L E C A R R I E R
M O D E L E M 4 0 5 D
COPYRIGHT
Copyright 2004 by C&H Technologies, Inc
DOCUMENT REVISION NOTICE
INTRODUCTION
TABLE OF CONTENTS
INSTALLATION
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTION
APPENDIX A - CONNECTORS
APPENDIX B - WIRED ETHERNET DEFAULT SETTINGS
APPENDIX C - WIRELESS ETHERNET WI-FI DEFAULT SETTINGS
LIST OF FIGURES
Figure 1. EM405D Ethernet M-Module Carrier 1.1 PURPOSE OF EQUIPMENT
1.2 FEATURES AND SPECIFICATIONS 1.2.1 Key Features
1.0 GENERAL DESCRIPTION
1.2.2 Specifications
CHARACTERISTICS
MAXIMUM RATINGS
Parameter
1.3 Electrical
1.4 Mechanical
1.5 Environmental
1.6 Bus Compliance
IEEE-802.3 ANSI 8802.3, Ethernet Network Standard
1.7 APPLICABLE DOCUMENTS
IEEE-802.11b, Wireless Ethernet Standard
2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION
2.2 HANDLING PRECAUTIONS
2.3 INSTALLATION OF M-MODULES
Figure 2. M-module Installation
MODULE A
Figure 3. M/MA Configuration Diagram
MODULE B
Figure 4. Functional Block Diagram 3.1.1 Embedded Controller
3.0 FUNCTIONAL DESCRIPTION 3.1 GENERAL
3.1.2 Ethernet Interface
ETHERNET
3.1.4 Power Conversion
3.1.3 M-module Interface
3.2 REAR PANEL
Figure 5. Rear Panel
EM405D ETHERNET M-MODULE CARRIER
3.3 FRONT PANEL
Figure 6. Front Panel
Page
4.2.1 IP Address
4.2 CONFIGURING THE ETHERNET INTERFACE
4.0 OPERATING INSTRUCTIONS 4.1 GENERAL
The default subnet mask is 4.2.3 Gateway
The default gateway address is 4.2.4 Port Numbers
The default port number for standard module access is
4.2.5 Wireless Settings
4.2.6 Performing the Configuration - Wired Ethernet
The default setting is Auto-Scan
The default settings are WEP disabled and WPA disabled
telnet x.x.x.x
4.2.7 Performing the Configuration - Wireless Ethernet Wi-Fi
4.2.7.1 Wed-based Configuration
Table I. Command Summary
4.3.1 Error Handling
4.3 COMMUNICATING WITH THE CARRIER AND M-MODULES
Table II. Status Code SC
Successful 0x00 The command completed successfully without error
4.3.2 Write Data command
4.3.3 Read Data command
4.3.4 Block Access
4.3.4.1 Block Write command
4.3.4.2 Block Read command
4.3.5 EM405D Configuration/Status Registers
Table III. Register Summary
Offset
Register
Reset Error & Manufacturer Identification
Device Identification
Hardware Version
Firmware Version
Reset & Trigger Control
Fan Control & Temperature Status
Figure 7. EM405D Registers continued
Module A Trigger B Direction 0 = input, 1 = output
4.4 CONTROLLING THE TRIGGERS
4.5 FAN AND TEMPERATURE CONTROL
C = TEMP - 281
Page
5 TRIGGER IN 6 GND 7 GND 8 GND 9 GND
Figure A-1. 9-Pin DSUB Connector
PIN DESCRIPTION 1 +12V INPUT 2 +12V INPUT 3 +12V INPUT 4 TRIGGER OUT
Page
Table B-1. Ethernet Interface Default Settings
Table B-1. Ethernet Interface Default Settings. continued
Table B-1. Ethernet Interface Default Settings. continued
OEM Configurable Pins
Email Notification
blank
Page
Table C-1. Wireless Ethernet Configuration Default Settings
IP Settings
Wireless LAN Settings
Wireless Security Settings
Advanced Network Settings
Port Profile Settings
TCP Server Settings
TCP Client Settings
blank
blank
blank
Page
N O T E S
Page
READERS COMMENT FORM
INSTRUCTIONS