1 Install the Safety Reversing Sensors

Option C FLOOR INSTALLATION

Use an extension bracket (not provided) or wood block to raise the sensor bracket if needed.

1.1C Carefully measure the position of both sensor brackets so they will be the same distance from the wall and unobstructed.

Inside

age

Gar

Wall

1.2C Attach the sensor brackets to the floor using concrete anchors (not provided).

(not provided)

 

e

Insid

G

arage

ll

Wa

1.3C Slide the carriage bolt (H17) into the slot on each sensor.

H17

1.4C Insert the bolt through the hole in the sensor bracket and attach with the wing nut (H18). The lenses on both sensors should point toward each other. Make sure the lens is not obstructed by the sensor bracket.

H18

sde

In age Gar Wall

2 Wire the Safety

Option A INSTALLATION WITHOUT PRE-WIRING

Reversing Sensors

PRE-WIRED INSTALLATIONS: If your garage already has wires installed for the safety reversing sensors, refer to the instructions on the following page.

HARDWARE

Insulated Staple (30)

2.1A Run the wire from both sensors to the garage door opener. Attach the wire to the wall and ceiling with the staples.

Staple

2.2A Strip 7/16 inch (11 mm) of insulation from each set of wires. Separate the wires.

Twist the white wires together. Twist the white/black wires together.

2.3A Insert the white wires into the white terminal on the garage door opener. Insert the white/black wires into the grey terminal on the garage door opener.

REDWHITEWHITEGREY

7/16"

(11 mm)

To insert or remove the wires from the terminal, push in the tab with a screwdriver tip.