Install the Protector System®

Option B PRE-WIRED INSTALLATION

2.1B Cut the end of the safety reversing sensor wire, making sure there is enough wire to reach the pre-installed wires from the wall.

2.2B Separate the safety reversing sensor wires and strip 7/16 inch (11 mm) of insulation from each end. Choose two of the pre-installed wires and strip 7/16 inch (11 mm) of insulation from each end. Make sure that you choose the same color pre-installed wires for each sensor.

Safety reversing sensor wires

7/16"

Pre-installed

wires

(11 mm)

 

 

7/16"

 

(11 mm)

2.3B Connect the pre-installed wires to the sensor wires with wire nuts making sure the colors correspond for each sensor. For example, the white wire would connect to the yellow wire and the white/black wire would connect to the purple wire.

Not Provided

White Yellow

(for example)

 

Pre-installed

 

wires

White/Black

Purple

(for example)

 

Safety sensor wires

2.4B At the garage door opener, strip 7/16 inch (11 mm) of insulation from each end of the wires previously chosen for the safety reversing sensors. Twist the like-colored wires together.

Yellow

Purple

7/16" (11 mm)

2.5B Insert the wires connected to the white safety sensor wires to the white terminal on the garage door opener. Insert the wires that are connected to the white/black safety sensor wires to the grey terminal on the garage door opener.

Yellow (for example)

Purple (for example)

RED

WHITE

EWHIT

GREY

To insert or remove the wires from the terminal, push in the tab with a screwdriver tip.

26