Power

2 Ensure the Safety Reversing Sensors are aligned

The door will not close if the sensors have not been installed and aligned correctly.

When the light beam is obstructed or misaligned while the door is closing, the door will reverse and the garage door opener lights will flash ten times. If the door is already open, it will not close.

The sensors can be aligned by loosening the wing nuts, aligning the sensors, and tightening the wing nuts.

2.1Check to make sure the LEDs in both sensors are glowing steadily. The LEDs in both sensors will glow steadily if they are aligned and wired correctly.

 

 

If the receiving sensor is in

 

 

 

 

 

 

 

 

 

 

direct sunlight, switch it with

 

 

 

 

 

 

 

 

 

 

sending sensor so it is on the

 

 

opposite side of the door.

Amber LED

 

 

 

Green LED

 

 

(invisible light beam)

SENDING SENSOR

RECEIVING SENSOR

IF THE AMBER LED ON THE SENDING SENSOR IS NOT GLOWING:

Make sure there is

Make sure the

Make sure the sensor has been wired

power to the garage

sensor wire is not

correctly: white wires to white terminal and

door opener.

shorted/broken.

white/black wires to grey terminal.

GREY

WHITE

WHITE

RED

3 Ensure the Door Control is wired correctly

IF THE GREEN LED ON THE RECEIVING SENSOR IS NOT GLOWING:

Make sure the sensor wire is

Make sure the sensors are aligned.

not shorted/broken.

 

If the door control has been installed and wired correctly, a message will display on the Smart Control Panel screen or the command LED on the Motion-Detecting Control Panel will blink.