Maintenance and Care

Resetting the Lamp Counter

Be sure to reset the Lamp counter after the lamp is replaced. When the Lamp counter is reset, the LAMP 1/2 REPLACE indicator stops lighting and the Lamp replacement icon disappears.

1

Press the MENU button to display the On-Screen Menu.

Lamp counter

Use the Point  buttons to move the red frame pointer

 

to the Setting Menu icon

2Use the Point ! buttons to move the red frame pointer to Lamp counter and then press the SELECT button.

A dialog box appears. Select a lamp and the “Lamp replacement counter Reset?” appears. Select [Yes] to continue.

3Another confirmation dialog box appears and select [Yes] to reset the Lamp counter.

Note:

s$O NOT RESET THE ,AMPECOUNTERHWITHOUTAREPLACINGOTHENLAMPR "EESURE TORRESETTTHE ,AMP COUNTER ONLYEAFTEREREPLACINGPTHEA LAMP

Select a lamp and the “Lamp replacement counter Reset?” appears.

Select [Yes], then another confirmation box appears.

Select [Yes] again to reset the lamp counter.

ORDER REPLACEMENT LAMP

Replacement Lamp can be ordered through your dealer. When ordering a Projection Lamp, give the following information to the dealer.

L

Model No. of your projector

:

LX1000

L

Replacement Lamp Type No.

:

003-120479-01

 

 

 

(Service Parts No. 610 341 9497)

62

LX1000 User Manual

 

020-000141-01 Rev. 1 (05-2009)