Power management

Setting

Power management

For reducing power consumption as well as maintaining the lamp life, the Power management function turns off the projection lamp when the projector is not used for a certain period.

If the input signal is interrupted and no button is pressed for more than 30 seconds, the timer display with “No signal” appears. It starts the countdown until the lamp is turned off. The countdown time can be set between 1 and 30 minutes.

Use the Point  buttons to set the countdown timer.

Select one of the following options:

Ready . . . . When the lamp has been fully cooled down, the POWER indicator starts blinking. In this condition, the projection lamp is turned on if the input signal is reconnected or any button on the side control or remote control is pressed .

Shutdown . . When the lamp has been fully cooled down, the power is turned off.

Off . . . . . . . Power Management function is off.

On start

When this function is set to “On,” the projector will be automatically turned on just by connecting the AC power cord to the wall outlet.

Note:

Make sure that the MAIN ON / OFF switch is ON, otherwise the On start function does not work.

Be sure to turn off the projector properly (see “Turning Off the Projector” on page 25). If the projector is turned off in the incorrect sequence, the On start function does not work properly.

Power management

Time left before the lamp is off

Press the SELECT button at Power management and the dialog box appears. Use the Point  buttons to choose one of the three options. Press the Point 4 button to select the timer, and then use the Point   buttons to set the timer.

Note:

•Factory default is “Ready: 5 min.”

•When the shutter is closed while the Power management function is working, the Power management function is released.