Chapter 3 Power Supply Installation

Power Supply Module Installation

Follow these steps to install a dual-hole lug on the switch. Be sure to follow any grounding requirements at your site.

Step 1 Use a Phillips screwdriver or a ratcheting torque screwdriver with a Phillips head to remove the ground screw from the cable side of the switch. You need the screw in Step 4.

Step 2 Strip the 6-gauge ground wire to 0.5 inch (12.7 mm) ± 0.02 inch (0.5 mm) (see Figure 3-3). Stripping more than the recommended amount of wire can leave exposed wire from the connector.

Figure 3-3 Stripping the Ground Wire

0.25 in. (6.3 mm) ± 0.02 in. (0.5 mm)

60531

Step 3 Insert the ground wire into the terminal lug, and crimp the terminal to the wire (see Figure 3-4).

Figure 3-4 Crimping the Terminal Lug

280938

Step 4 Slide the ground screw from Step 1 through the terminal lug. Insert the ground screws into the opening on the cable side.

Figure 3-5 Attaching the Terminal Lug

100-240V~, 50-60Hz,2A

Cisco

1

207217

1

Dual-hole terminal lug

Cisco CGS 2520 Hardware Installation Guide

 