Appendix A Troubleshooting

Error Messages

Table A-10 Cisco 3660 System Error and Status Messages (continued)

LED Type

LED Color

Message

 

 

 

System

Amber

Error:

 

 

%SYS-1-OVERTEMP: System detected OVERTEMPERATURE condition. Please resolve cooling

 

 

problem immediately!

 

 

Explanation:

 

 

The router is operating at an abnormally high temperature, possibly caused by one or more of

 

 

the following:

 

 

Fan failure

 

 

Air conditioner failure in the room

 

 

Air blockage to cooling vents

 

 

Recovery:

 

 

Check the possible causes. See also the “Site Environment” section on page 2-4and the

 

 

“Equipment Racks” section on page 2-5.

 

 

When the error condition is resolved, the following informational message appears:

 

 

%OVERTEMP_OK, PS, LOG_ERR, 0: System temperature is now normal.

 

 

 

System

Amber

Error:

 

 

%THERMAL-3-PS: System detected Power System # THERMAL FAIL condition.

 

 

Explanation:

 

 

The operating temperature of the specified power supply (1 or 2) exceeded the acceptable

 

 

range possibly caused by one or more of the following:

 

 

Fan failure

 

 

Air conditioner failure in the room

 

 

Air blockage to cooling vents

 

 

Recovery:

 

 

Check the possible causes. If the fan has failed, replace the fan cage. Refer to the Replacing

 

 

the Fan Cage in Cisco 3660 Routers hardware configuration note.

 

 

When the error condition is resolved, the following informational message appears:

 

 

%THERMOK-3-PS: Power System THERMAL condition is now normal.

 

 

 

 