Configuring the SDC 8200 system

Diagnostics

1Port Errors

Port Errors

 

 

 

 

 

 

[!]

 

 

P1

P2

P3

P4

P5

P6

Checking the communication within a cable string

To display if and on which port(s) a communications error has occured:

￿From the central unit’s operating menu, choose “System”, “Diagnostics” and “Port Errors” one after the other.

The ports “P1“ to “P6“ with a respective symbol are shown on the dis- play.

The symbols have the following meanings:

: A cable string with consoles is connected to the port.

: No cable string is connected to the port. If this symbol appears even though a cable string is connected to the port, check if the cable string is connected correctly.

[!]: A communications error has occured. This symbol only appears if a cable string is connected to the port.

System

2Camera Conrol

Camera Control

Status = OFF

Press ENTER to Save

System

3Control Panel

Control Panel

Status = OFF

Press ENTER to Save

Configuring connected additional components

Turning on/off a camera control

If you connect an external camera control to the central unit, you have to activate the camera control via the central unit’s operating menu.

To turn a connected camera control on:

￿From the central unit’s operating menu, choose “System” and “Camera Control” one after the other.

The current status of the camera control is shown on the display.

￿Choose “Status = ON” and press the ENTER key to save your setting.

Turning on a connected control panel

instead of controlling the SDC 8200 conference and interpretations system via a PC with software control, you can use a control panel (optional). The control panel is a miniature physical representation of your conference room, allowing you to turn on or off individual conference consoles, change the volume, change the conference mode, display the status of the inter- preter booths, etc.

The control panel will be custom tailored to your specific requirements.

To turn a connected control panel on:

￿From the central unit’s operating menu, choose “System” and “Control Panel” one after the other.

The current status of the control panel is shown on the display.

￿Choose “Status = ON” and press the ENTER key to save your setting.