Setting up the SDC 8200 system

Setting up the SDC 8200 system

This chapter provides information on how to set up and operate the

SDC 8200 conference and interpretation system.

Preparing the SDC 8200 system components for set up

Conference and interpreter consoles

After unpacking the consoles, you simply have to connect them to the cen- tral unit and initialize them.

Central unit

Warning!

Danger of life-threatening electric shock!

If you connect the central unit to an ungrounded power outlet, persons touching the central unit or units con- nected to it may receive a life-threatening electric shock.

￿Connect the central unit only to properly grounded power outlets.

￿ Connect the mains cable to socket .

￿Connect the mains cable to the mains (100 – 240 V, 50 – 60 Hz).

Rack-mounting several SDC 8200 CU central units

For larger conference and interpretation systems with several SDC 8200 CU central units, we recommend mounting the central units into a rack.

Caution!

Danger of heat damage!

When rack-mounting the central units, please consider that, during operation, the ambient temperature within the rack may significantly rise above room temperature. The central units can be damaged by high temperatures.

￿The ambient temperature within the rack must not exceed the temperature limit specified in the specifi- cations.

￿Make sure not to affect the ventilation required for safe operation or provide additional ventilation.

52

Page 52
Image 52
Sennheiser Setting up the SDC 8200 system, Preparing the SDC 8200 system components for set up, Central unit