Setting up the SDC 8200 system
tem installed in a separate room to carry out a remote conference. The par- ticipants of both conferences can then participate in a common confer- ence.
To connect two conference systems installed in separate rooms, you require two XLR cables with two
Connect the audio input AUX IN 1 | of the first central unit to the audio |
output AUX OUT 1 of the secend central unit. | |
Connect the audio input AUX IN 1 | of the secend central unit to the |
audio output AUX OUT 1 of the first central unit.
From the central unit’s operating menu, choose “Dist. Conf. = ON” to prevent echo (see “Configuring the audio outputs for remote confer- encing” on page 107).
Connecting PA systems, recording units, etc.
Via the audio outputs you can connect e.g. a PA system, a recording unit, etc.
Connect the desired unit as follows:
The signals of the floor channel are available at the
put AUX OUT 1 and the
The signals of up to four interpretation channels are available at the
outputs AUX OUT
If an SDC 8200 AO analog output unit is connected to the DATA OUT
socket of the SDC 8200 CU central unit, additional channels can be output via the analog output unit’s
Pin assignment of the 15-pole sub-D socket (AUX OUT 2-3-4-5-6)
When connecting external equipment to the
PIN | SIGNAL | PIN | SIGNAL |
1+9 | Aux Out 1 | 6+14 | Aux Out 6 |
2+10 | Aux Out 2 | 7 | not assigned |
3+11 | Aux Out 3 | 8 | not assigned |
4+12 | Aux Out 4 | 15 | not assigned |
5+13 | Aux Out 5 |
|
|
The audio signal of the floor channel is always available at the two outputs AUX OUT 1
The channel assignment for the four other audio outputs can be changed as described in the section “Assigning a channel to an audio output” on page 105. You can assign these outputs any interpretation channel or the floor channel.
Note!
The audio signal of the channel assigned to the output AUX OUT 6 (pin
6and 14 of the
57