Sennheiser SDC 8200 system manual 123, 1X06060606

Models: SDC 8200

1 128
Download 128 pages 11.95 Kb
Page 123
Image 123

123

The commands sent by the central unit and received by the control panel:

General syntax

General meaning

 

Examples

 

 

 

 

 

 

 

 

{'%'}{'1'}{'L'}{Mic.-No.(4)}{CRC(4)}

A microphone is activated.

%L0001013E

The microphone with the number '0001' is acti-

 

 

 

vated.

 

 

 

 

{'%'}{'1'}{'l'}{Mic.-No.(4)}{CRC(4)}

A microphone is deactivated.

%1l0001015E

The microphone with the number '0001' is deacti-

 

 

 

vated.

 

 

 

 

{'%'}{'1'}{'D'}{Mic.-No.(4)}{CRC(4)}

A microphone goes into request.

%1D00020137

The microphone with the number '0002' goes into

 

 

 

request mode.

 

 

 

 

{'%'}{'E'}{'00'}{CRC(4)}

All microphones should be reset (priority function).

%1E0000D6

All microphones are turned off.

 

 

 

 

The commands sent by the control panel and received by the central unit:

General syntax

General meaning

 

Examples

 

 

 

 

 

 

 

 

{'%'}{'1'}{'T'}{Mic.-No.(4)}{CRC(4)}

Activate a microphone.

%1T00020147

The microphone with the number '0002' is to be

 

 

 

activated.

 

 

 

 

 

Restart the control panel and get information

 

The control panel is to be restarted and the correct

{'%'}{'1'}{'V'}{CRC(4)}

about the microphones to reinitialize the control

%1V0087

information about all active microphones and all

 

panel.

 

microphones in request mode is to be received.

 

 

 

 

{'%'}{'1'}{'X'}{Volume(2)}{Treble

 

%1X06060606

Volume, treble, middle and bass response are each

Change the volume and sound settings of the con-

0221

to be set to the value “06”.

response(2)}{Middle response(2)}{Bass

soles’ built-in loudspeakers.

 

 

response(2)}{CRC(4)}

%1X00060606

All microphones are to be muted.

 

 

 

021B

 

 

 

 

 

{'%'}{'1'}{'U'}{Conference mode(2)}{CRC(4)}

Change the conference mode.

%1U0400EA

The conference mode is to be changed to “FIFO”

mode.

 

 

 

 

 

 

 

{'%'}{'1'}{'v'}{CRC(4)}

Activate the test tone.

 

 

 

 

 

 

{'%'}{'1'}{'w'}{CRC(4)}

Deactivate the test tone.

 

 

 

 

 

 

Notation of the general syntax:

All separate entities in a message are represented between curly brackets, e.g. {CRC}

Literal strings are between quotes, e.g. 'P'

Logical entities are neither between brackets nor quotes, e. g. Mic.-No.(microphone number)

A logical entity will also contain a number between brackets. This number states how many characters the entity exists of, e.g.(4)

Volume, treble, middle and bass response are two-digit values from “00” (minimum) to “12” (maximum)

The two-digit numbers for the conference modes are: “00” (No Request), “01” (With Request), “02” (With Req. No Clear), “03” (Direct Access), “04” (FIFO),

Appendix B: Control panel protocol

Page 123
Image 123
Sennheiser SDC 8200 system manual 123, 1X06060606