DLP-D223 Download an Alarm Severity Profile

Chapter 19 DLPs D200 to D299

DLP- D223 Download an Alarm Severity Profile

Note Reprovisioning an Ethernet port on the G-Series card does not reset the Ethernet statistics for that port.

Step 6 Return to your originating procedure (NTP).

DLP-D223 Download an Alarm Severity Profile

Purpose

This task downloads a custom alarm severity profile from a network-drive

 

accessible CD-ROM, floppy disk, or hard disk location.

Tools/Equipment

None

Prerequisite Procedures

DLP-D60 Log into CTC, page 17-49

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Step 1 To access the alarm profile editor from network view, click the Provisioning > Alarm Profiles tabs.

Step 2 To access the profile editor from node view, click the Provisioning > Alarm Profiles > Alarm Profile Editor tabs.

Step 3 To access the profile editor from a card view, click the following tabs:

If the card is an E-Series Ethernet, G-Series Ethernet, STM-N, or electrical (DS3i-N-12, E1-N-14, E1-42, or E3-12) card, click the Provisioning > Alarm Profiles > Alarm Profile Editor tabs.

If the card is an ML-Series Ethernet (traffic) card, click the Provisioning > Ether Alarming > Alarm Profile Editor tabs if you want to apply the profile to the front physical ports, or the Provisioning > POS Alarming > Alarm Profile Editor tabs if you want to apply the profile to the packet over SDH (POS) ports. For more information about ML-Series card ports and service, refer to the Ethernet Card Software Feature and Configuration Guide for the Cisco ONS 15454, Cisco ONS 15454 SDH, and Cisco ONS 15327.

If the card is an FC_MR-4 card, click the Provisioning > Alarm Profiles > Alarm Profile Editor tabs.

Step 4 Click Load.

Step 5 If you want to download a profile that exists on the node, click From Node in the Load Profile(s) dialog box.

a.Click the node name you are logged into in the Node Names list.

b.Click the name of the profile in the Profile Names list, such as Default.

Step 6 If you want to download a profile that is stored locally or on a network drive, click From File in the Load Profile(s) dialog box.

a.Click Browse.

b.Navigate to the file location in the Open dialog box.

c.Click Open.

 

 

Cisco ONS 15454 SDH Procedure Guide, R7.2

 

 

 

 

 

 

October 2007

 

 

19-23

 

 

 

 

 