DLP-D263 Edit SNCP Dual-Ring Interconnect Circuit Hold-Off Timer

Chapter 19 DLPs D200 to D299

DLP- D263 Edit SNCP Dual-Ring Interconnect Circuit Hold-Off Timer

Step 5 Click OK. Circuits matching the attributes in the Filter Circuits dialog box appear in the Circuits window.

Step 6 To turn filtering off, click the Filter icon in the lower right corner of the Circuits window. Click the icon again to turn filtering on, and click the Filter button to change the filter attributes.

Step 7 Return to your originating procedure (NTP).

DLP-D263 Edit SNCP Dual-Ring Interconnect Circuit Hold-Off Timer

 

Purpose

This task changes the amount of time a path selector switch is delayed for

 

 

circuits routed on an SNCP dual-ring interconnect (DRI) topology. In

 

 

DRIs, switching contention might occur depending upon the relative

 

 

switching speed of the path selector and the transmission delay on the

 

 

alternative routes. The hold-off time (HOT) allows you to change switch

 

 

times to prevent the switching contention.

 

Tools/Equipment

None

 

Prerequisite Procedures

NTP-D44 Provision SNCP Nodes, page 5-22

 

 

DLP-D60 Log into CTC, page 17-49

 

Required/As Needed

As needed

 

Onsite/Remote

Onsite or remote

 

Security Level

Provisioning or higher

 

 

Step 1

From the View menu, choose Go to Network View.

Step 2

Click the Circuits tab.

 

Step 3

Click the SNCP circuit you want to edit, then click Edit.

Step 4

In the Edit Circuit window, click the SNCP Selectors tab.

Step 5

In the Hold-off Timer column, double-click the cell of the circuit span you want to edit, then type the

 

new hold-off time. The range is 0 to 10,000 ms in increments of 100.

Step 6

Repeat Step 5, as needed, to adjust the hold-off timer for each circuit span.

Step 7

Click Apply, then close the Edit Circuit window by choosing Close from the File menu.

Step 8

Return to your originating procedure (NTP).

 

 

 

 