DLP-D205 Clean Fiber Connectors with CLETOP

Chapter 19 DLPs D200 to D299

DLP- D205 Clean Fiber Connectors with CLETOP

Step 3 Blow-dry using filtered air.

Step 4 Use an inspection microscope to inspect each fiber connector for dirt, cracks, or scratches. If the connector is not clean, repeat Steps 1 to 3.

Step 5 Insert the fiber connector into the applicable adapter or attach a dust cap to the fiber connector.

Note If you must replace a dust cap on a connector, first verify that the dust cap is clean. To clean the dust cap, wipe the outside of the cap using a dry, lint-free wipe and the inside of the dust cap using a CLETOP stick swab (14100400).

Step 6 Return to your originating procedure (NTP).

DLP-D205 Clean Fiber Connectors with CLETOP

 

Purpose

This task cleans the fiber connectors with CLETOP.

 

Tools/Equipment

“Type A” Fiber Optic Connector Cleaner (CLETOP reel)

 

 

 

 

Optical receiver cleaning stick

 

Prerequisite Procedures

None

 

Required/As Needed

Required

 

Onsite/Remote

Onsite

 

Security Level

None

 

 

 

 

Step 1

Remove the dust cap from the fiber connector.

Step 2

Press the lever down to open the shutter door. Each time you press the lever, you expose a clean wiping

 

surface.

 

 

Step 3

Insert the connector into the CLETOP cleaning cassette slot, rotate one quarter turn, and gently swipe

 

downwards.

 

Step 4

Use an inspection microscope to inspect each fiber connector for dirt, cracks, or scratches. If the

 

connector is not clean, repeat Steps 1 to 3.

Step 5

Insert the fiber connector into the applicable adapter or attach a dust cap to the fiber connector.

 

 

 

 

 

Note

If you must replace a dust cap on a connector, first verify that the dust cap is clean. To clean the

 

 

 

dust cap, wipe the outside of the cap using a dry, lint-free wipe and the inside of the dust cap

 

 

 

using a CLETOP stick swab (14100400).

 

 

 

Step 6

Return to your originating procedure (NTP).

 

 

 

 

 

 