Cisco IE 3000 Switch Getting Started Guide
Step 7 Connect the other end of the positive wire (the one connected to V) to the positive terminal on the DC power source, and connect the other end of the return wire (the one connected to RT) to the return terminal on the DC power source.
Step 8 When you are testing the switch, one power connection is sufficient. If you are installing the switch and are using a second power source, repeat Step 3 through Step 7 using a second power and relay connector.
Attaching the Power and Relay Connector
Follow these steps to connect the DC power and relay connector to the switch:
Caution The input voltage source of the alarm circuits must be an isolated source and limited to less than or equal to 30 VDC, 1 A.
Step 1 Insert the power and relay connector into the Pwr A receptacle on the switch front panel.
V RT A A
202332
Step 2 Use a flathead screwdriver to tighten the captive screws on the sides of the power and relay connector.
| Cisco IE 3000 Switch Getting Started Guide |
20 |