Cisco Systems IE 3000 Series Connecting the Protective Ground and DC Power, Grounding the Switch

Models: IE 3000 Series IEM30004PC

1 170
Download 170 pages 5.73 Kb
Page 39
Image 39

Chapter 2 Switch Installation

Verifying Switch Operation

Step 5 Connect the other end of the adapter cable to the PC or terminal adapter.

Step 6 Start the terminal-emulation software on the PC.

Connecting the Protective Ground and DC Power

These sections describe the steps required to connect a protective ground and DC power to the switch:

Grounding the Switch, page 2-13

Wiring the DC Power Source, page 2-16

Attach the Power and Relay Connector to the Switch, page 2-21

Note The Cisco IE 3000 switch can be used with an optional AC/DC power converter (PWR-IE3000-AC).

For instructions on how to connect the power converter to the switch, see the “Connecting the Switch to the Power Converter” section on page 2-44.

Locate the power and relay connector in the switch accessory kit.

Note You can get replacement power and relay connectors (PWR-IE3000-CNCT=) by calling Cisco Technical Support. See the “Obtaining Documentation, Obtaining Support, and Security Guidelines” section on page x.

Obtain these necessary tools and equipment:

Ratcheting torque flathead screwdriver that exerts up to 15 inch-pounds (in-lb) of pressure

Ring terminal lug (such as Thomas & Bett part number 10RCR or equivalent)

Crimping tool (such as Thomas & Bett part number WT2000, ERG-2001, or equivalent)

10-gauge copper ground wire (such as Belden part number 9912 or equivalent)

For DC power connections, use UL- and CSA-rated, style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire (such as Belden part number 9318).

Wire-stripping tools for stripping 10- and 18-gauge wires

Grounding the Switch

To ground the switch to earth ground by using the ground screw, follow these steps. Make sure to follow any grounding requirements at your site.

Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024

 

 

Cisco IE 3000 Switch Hardware Installation Guide

 

 

 

 

 

 

OL-13017-01

 

 

2-13

 

 

 

 

 

Page 39
Image 39
Cisco Systems IE 3000 Series, IEM30004PC manual Connecting the Protective Ground and DC Power, Grounding the Switch