Removing a VIP6-80
This section describes the procedure for removing a
Caution If your router has an RSP2 as the standby with the high system availability (HSA) feature or high availability (HA) features enabled, online insertion and removal of any interface processor in either CyBus might cause the standby RSP2 to reboot with a bus error or a processor memory parity error. The active RSP recovers from this event and issues a “cBus Complex Restart” message. Systems that are configured with an RSP4/4+, an RSP8, or an RSP16 as the system standby are not affected and do not experience this problem. For more information on HSA or HA, refer to your RSP installation and configuration guide.
If your router has an RSP2 as the standby with the HSA feature or HA features enabled, perform the following steps before proceeding with the
Step 1 Attach an
Step 2 Remove the standby RSP2.
Step 3 Wait 20 to 30 seconds. This time will vary depending on the number of interfaces installed on your system.
This completes the additional steps you must perform if you have an RSP2 configured as the standby with HSA or HA enabled. Continue with the following steps to finish the removal of the
Perform the following steps to remove a
Step 1 Attach an
Step 2 Disconnect all cables from the
Step 3 Use a screwdriver to loosen the captive installation screws at both ends of the board. (See Figure 3a.)
Caution Always use the ejector levers to remove a
Step 4 Place your thumbs on the ejector levers and simultaneously pull both of the ejector levers outward (in the direction shown in Figure 3a) to release the board from the backplane connector.
•Use the board’s handle to carefully pull it straight out of the slot, keeping your other hand under the carrier to guide it. (See Figure 3c.) Keep the board parallel to the backplane.
•If you removed a
Versatile Interface Processor
18 |
| |
|