Safety Guidelines

Chapter 2 Preparing to Install the WAVE-594 and WAVE-694

Safety Guidelines

Warning

Warning

Warning

Warning

Warning

Caution

Caution

This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024

This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028

Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030

This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045

Installation of the equipment must comply with local and national electrical codes. Statement 1074

To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the WAVE appliance.

To reduce the risk of electric shock or damage to the equipment:

-Do not disable the power cord grounding plug. The grounding plug is an important safety feature.

-Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.

-Unplug the power cord from the power supply to disconnect power to the equipment.

-Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the WAVE appliance.

Caution To reduce the risk of personal injury or damage to the equipment:

-Observe local occupation health and safety requirements and guidelines for manual handling.

-Obtain adequate assistance to lift and stabilize the chassis during installation or removal. The WAVE appliance is unstable when not fastened to the rails. When mounting the WAVE appliance in a rack, remove the power supplies and any other removable module to reduce the overall weight of the product.

Safety Guidelines

To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the precautions in this section.

This section contains the following topics:

General Precautions, page 2-4

Cisco Wide Area Virtualization Engine 594 and 694 Hardware Installation Guide

2-2

OL-24619-02

 

 

Page 24
Image 24
Cisco Systems WAVE594K9, 694 manual Safety Guidelines, General Precautions, page