Replacing a Power Supply

Chapter 4 Installing Hardware Options for the WAVE-594 and WAVE-694

Replacing a Power Supply

Figure 4-3

Fan Assembly

1 Manual backgroundManual backgroundManual backgroundManual background

2

246554

Step 3 Within one minute, insert the new fan with the surface marked “TOP” facing up and verify that the latch is engaged.

Step 4 Check the power LED to verify that the new fan is receiving power.

Note If a fan alarm occurs and you power down the WAVE appliance to replace the fan, you must use the clear bmc event-logglobal configuration command and then reboot to clear the alarm.

Replacing a Power Supply

The WAVE appliance supports two power supply assemblies that are hot-swap capable.

Power supply assemblies can only be inserted in one orientation.

Note Power supply assemblies must be inserted and can only function with the surface marked “TOP” facing up.

Caution To maintain proper system cooling, do not operate the appliance for more than 1 minute without either a power supply or a filler panel installed in each bay.

To replace a power supply assembly, follow these steps:

Step 1 Review the information in the “Safety Warnings and Cautions” section on page 2-1and the “Safety Guidelines” section on page 2-2.

Step 2 Remove the power cord from the power supply.

Note When more than one power supply assembly is present, load-sharing is supported. If one loses power, the second power supply takes over.

Cisco Wide Area Virtualization Engine 594 and 694 Hardware Installation Guide

 