4.Electrical Characteristics 4.1 In/output signals

(1)RD

When a framing error, overrun error or parity error occurs, the data containing the error is printed as a “?”.

(2)DSR

If the DTR/SDR control is selected, the host sends data to the printer after it confirms that the DSR line is at space. If the XON/XOFF control is selected, the host sends data to the printer by ignoring the DSR signal status.

(3)INIT

This signal can be used as a reset signal after switching the DIP switches. When the pulse width of the signal is 1 ms or longer in space state, a reset will be applied.

* Mark=logical “1” (–3 V to –12 V)

* Space=logical “0” (+3 V to +12 V)

4.2 Data Configuration

 

 

 

 

 

t

 

Mark

b0, b1, b2 ...

 

 

 

 

 

Space

 

(1)

Start Bit

 

 

 

 

(2)

Data Bit (+Parity Bit)

 

 

(3)

Stop Bit

(1)

(2)

(3)

 

Data status is read again 1/2 bit time after the falling edge of mark to space transition. If a space is detected, the data is recognized as a start bit. If a space is not detected, the data is not recognized as a start bit, and attempt is made again to detect a start bit.

The data is sampled 1 bit time after the start bit is detected.

Data bits are arranged in the order of bit 0, bit 1, bit 2, ...., and (stop bit), from the

start bit toward stop bit.