ESC c 5 n

[Function]

Enabling/Disabling the panel switches

[Code]

<1B>H<63>H<35>H<n>

[Range]

0 n 255

[Outline]

Enabling/disabling the FEED switch.

 

• “n” is valid only in the lowest bit.

n0

0

1

Condition

FEED switch valid

FEED switch invalid

[Caution]

When the panel switch is disabled with this command, the FEED

 

switch is also disabled. Therefore, the paper cannot be fed by

 

operating the FEED switch. Regardless of the setting of this

 

command, the FEED switch is always enable while the switch is

 

being waited for at the time of macro execution.

[Default]

n = 0

[Sample Program]

 

LPRINT CHR$(&H1B) + “c5” + CHR$(0);

When enabling the FEED switch

LPRINT CHR$(&H1B) + “c5” + CHR$(1);

When disabling the FEED switch

— 48 —