Meter type definitions

80

Appendix— Serial Commands

Meter type definitions

Alpha

Numeric

Level position

Level position

Level position

Level position

Level position

 

 

for Mic Pods

for Line Inputs

for Outputs

for Telco Transmits

for Telco Receives

A

2

Maximum level

Level after PEQ

Level after PEQ

Level after gain

Level after gain

 

 

of the three

and gain

and gain

 

adjustment

 

 

microphones on the

 

 

 

 

 

 

pod after processing

 

 

 

 

 

 

 

 

 

 

 

R

5

Echo Return Loss

N/A

N/A

N/A

N/A

E

6

Echo Return Loss

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

T

7

ERL + ERLE

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

Serial command error codes

Error number

Text message

Explanation/Solution

1

Memory error

The box is out of internal memory.

 

 

Power cycle the box.

2

No command found

A command was not found in the string.

3

Unknown command

A command was executed on a different

 

 

device type that this box response can

 

 

not display. The command dictionary

 

 

needs to be updated.

4

Not implemented

The command is not implemented.

5

Argument error

The command had an argument that was

 

 

out of range.

6

Unknown command

The command is unknown to this unit.

7

Bad checksum

The binary command’s checksum is

 

 

wrong.

8

Camera not responding

A preset or macro failed to program

 

 

because it is too large or because its

 

 

command list contained an invalid

 

 

command.

11

Command too big

The binary command is too large.

Appendix— Serial Commands

 

81

 

RAV serial commands

Command

Function

AA

Selects/reports setting of auto answer

AARINGS

Selects/reports setting of the number of rings to auto answer

ACONN

Selects/reports status of audible connect/disconnect indication

AD

Selects/reports setting of auto disconnect

AEC

Selects/reports acoustic echo canceller setting

AECREF

Enables/disables or reports current status of AEC reference

AGC

Selects/reports AGC

BATTERYLVL

Reports battery level on remote

BAUD

Selects/reports the baud rate of the serial port

CALLDUR

Indicates how long a call has lasted

CAMBAUD

Selects/reports baud rate of camera control port

CAMCTRLMODE

Sets/reports camera control port mode

CAMFLOW

Selects/reports flow control of camera control port

CAMMOVE

Sends command to move the camera on the camera control port

CAMPRESET

Executes camera preset

CAMPRESETSET

Sets current position of camera as preset

CAMPRESETSET2

Sets/reports current camera preset

CAMPOSITION

Sets/reports current position of camera on the camera control port

CAMSWITCHLAG

Set the switch time lag for voice tracking

CAMTRACK

Selects/reports camera voice-tracking mode

CAMZOOM

Sets/reports current zoom of camera on the camera control port

CLEAREFFECT

Enables/disables or reports current status of clear effect

CLOCK

Sets/reports current time

COUNTRY

Sets/reports country for compliance

DEFAULT

Sets the unit to default

DEVICE

Selects/reports manufacturer identification label

DEVICETYPE

Enables /disables or reports the current type of device connected to

 

an input or output

DIAL

Dials DTMF sequence or reports last sequence dialed

DID

Selects/reports device ID

ENETADDR

Selects/reports IP address of the Ethernet port

ENETDHCP

Selects/reports use of DHCP of the Ethernet port

ENETDNSA

Selects/reports DNS server IP address of the Ethernet port

ENETDNX

Selects/reports use of the DNS of the Ethernet port

ENETGATE

Selects/reports default gateway of the Ethernet port

ENETSUBN

Selects/reports subnet mask of the Ethernet port

EQ

Enables/disables or reports current status of equalization

EQSEL

Enables/disables or reports current status of equalization

FLOW

Selects/reports the flow control of the serial port

GAIN

Changes/reports gain for a channel

GATE

Reports gate status of microphones

GREPORT

Selects/reports gate status report frequency

HOOK

Sends a hook flash

HOOKD

Selects/reports hook flash duration