ClearOne comm 600, 900 BATTERYLVL - Battery Level, BAUD - Baud Rate, CALLDUR - Call Duration

Models: 900

1 63
Download 63 pages 19.21 Kb
Page 46
Image 46
BATTERYLVL - Battery Level

86

Appendix — Serial Commands

BATTERYLVL - Battery Level

This command reports the battery level on the remote. If the batteries run low, this command will automatically be sent out reporting the low indication.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Value

Unsigned Integer

4

0

= battery level unavailable

 

 

 

 

1

= Lowest

 

 

 

 

2

 

 

 

 

 

3

 

 

 

 

 

4

 

 

 

 

 

5

= Highest

 

 

 

 

(Null to query in text.)

 

BINARY FORM DETAILS

 

 

 

 

COMMAND ID:

65

 

 

 

NUMBER OF ARGUMENTS: 1

 

 

 

ARGUMENT FORM: <Value>

 

 

 

 

TEXT FORM DETAILS

COMMAND FORM DEVICE BATTERYLVL [Value]

BAUD - Baud Rate

This command selects/reports the baud rate of the serial port.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Value

Unsigned Integer

4

9600, 19200, 38400,

 

 

 

 

57600,115200

 

 

 

 

(Null to query in text)

 

BINARY FORM DETAILS

 

 

 

COMMAND ID:

2

 

 

NUMBER OF ARGUMENTS: 1

 

 

ARGUMENT FORM:

<Value>

 

 

TEXT FORM DETAILS

 

 

 

COMMAND FORM:

DEVICE BAUD [Value]

 

Attention: If you are connected to the RAV unit through the serial port, you will need to reboot the unit before the baud rate and flow control changes take place. If you are connected to the RAV unit through the USB port, changes are made instantly.

Appendix— Serial Commands

 

87

 

CALLDUR - Call Duration

This command indicates how long a call has lasted. If no call is in session, this will report 0. At the time of call termination, this command will automatically be sent out reporting the duration.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group And Channels

 

Group

Group

1

17 (R)

 

Reserved

 

2

0

 

Duration

String

8

String of format

 

 

 

 

HR:MN:SS

 

BINARY FORM DETAILS

 

 

COMMAND ID:

 

63

 

NUMBER OF ARGUMENTS: 3

 

ARGUMENT FORM:

 

<Channel><Group><Reserved><Duration>

TEXT FORM DETAILS

COMMAND FORM:DEVICE CALLDUR <Channel> <Duration>

CAMBAUD - Camera Control Baud Rate

This command selects/reports the baud rate of the camera control serial port.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Value

Unsigned Integer

4

2400, 9600, 19200, 38400

 

 

 

 

(Null to query in text)

 

BINARY FORM DETAILS

 

 

 

COMMAND ID:

60

 

 

NUMBER OF ARGUMENTS: 1

 

 

ARGUMENT FORM:

<Value>

 

 

TEXT FORM DETAILS

 

 

 

COMMAND FORM:

DEVICE CAMBAUD [Value]

 

CAMCTRLMODE - Camera Control Port Mode

This command sets/reports the camera control port mode.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Value

Unsigned Integer

4

0 = Sony

 

 

 

 

1 = Canon

 

 

 

 

(Null to Query in Text)

 

BINARY FORM DETAILS

 

 

 

COMMAND ID:

50

 

 

NUMBER OF ARGUMENTS: 1

 

 

ARGUMENT FORM:

<Value>

 

 

TEXT FORM DETAILS

 

 

 

COMMAND FORM:

DEVICE CAMCTRLMODE [Value]

 

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760