ClearOne comm 600, 900 EQ - Equalization, EQSEL - Equalization Enable, FLOW - Flow Control

Models: 900

1 63
Download 63 pages 19.21 Kb
Page 52
Image 52
EQ - Equalization

98

Appendix — Serial Commands

EQ - Equalization

This command enables/disables or reports the current status of the equalization on the input or out- put.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group and Channels

 

Group

Group

1

2, 7 (O, L)

 

High Gain

Signed Float

2

-12.00 - 12.00

 

 

 

 

(Null to query in text)

 

Mid Gain

Signed Float

2

-12.00 - 12.00

 

Low Gain

Signed Float

2

-12.00 - 12.00

 

BINARY FORM DETAILS

 

 

 

COMMAND ID:

67

 

 

 

NUMBER OF ARGUMENTS: 2

 

 

 

ARGUMENT FORM:

<Channel><Group><High Gain><Mid Gain><Low Gain>

TEXT FORM DETAILS

 

 

 

COMMAND FORM:

DEVICE EQ <Channel> <Group> [High Mid Low]

 

EQSEL - Equalization Enable

This command enables/disables or reports the current status of the equalization on the input or out- put.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group and Channels

 

Group

Group

1

2, 7 (O, L)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(NULL to query in text)

 

BINARY FORM DETAILS

 

 

 

 

COMMAND ID:

74

 

 

 

NUMBER OF ARGUMENTS: 1

 

 

 

ARGUMENT FORM:

<Channel><Group><Value>

 

TEXT FORM DETAILS

 

 

 

 

COMMAND FORM:

DEVICE EQSEL <Channel> <Group> [Value]

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendix— Serial Commands

 

99

 

FLOW - Flow Control

This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented using DTR and DSR.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Value

Unsigned Integer

4

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

BINARY FORM DETAILS

 

 

 

 

COMMAND ID:

4

 

 

 

NUMBER OF ARGUMENTS: 1

 

 

 

ARGUMENT FORM:

<Value>

 

 

 

TEXT FORM DETAILS

 

 

 

 

COMMAND FORM:

DEVICE FLOW [Value]

 

GAIN - Gain Adjustment

This command changes or reports back the gain for a channel.

ARGUMENT DETAILS

 

 

 

Name

Type

Size

Values

Units

Channel

Channel

1

See Group and Channels

 

Group

Group

1

2, 3, 7, 16, 17 (O, M, L,T, R)

 

Value

Signed Float

2

-99.90 - 99.90 **(Null to query in text)

DB

Absol / Rel

 

0

A = Absolute R = Relative Null = Relative

 

BINARY FORM DETAILS

 

 

 

COMMAND ID:

5

 

 

NUMBER OF ARGUMENTS: 1

 

 

ARGUMENT FORM:

<Channel><Group><Value>

 

TEXT FORM DETAILS

 

 

 

COMMAND FORM:

DEVICE GAIN <Channel> <Group> [Value] [Absol/Rel]

Note: Values indicate entry range only. Actual internal range of the gain stage is from -14 to 18. Absolute values will be limited to the internal gain range.

GATE - Gate Status

This command reports the gate status of mics.This command is read-only.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Value

Hexadecimal

4

Bits 0 - 8 represent

 

 

 

 

gate status on Mics 1 - 9

 

 

 

 

(Null sent in text, Value returned)

 

 

 

 

Mic 1 = LSB, Mic 2 =MSB

 

BINARY FORM DETAILS

 

 

 

COMMAND ID:

6

 

 

NUMBER OF ARGUMENTS: 1

 

 

ARGUMENT FORM:

<Value>

 

 

TEXT FORM DETAILS

 

 

 

COMMAND FORM:

DEVICE GATE [Value]

 

 

 

 

 

 

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 52
Image 52
ClearOne comm 600, 900 EQ - Equalization, EQSEL - Equalization Enable, FLOW - Flow Control, GAIN - Gain Adjustment