To change the User Name and Password

 

32

 

RAV-Ware— Configuring System Settings

To change the User Name and Password

1.In the Networking tab, click User/Password.

2.Specify the User name. (Default is clearone.)

3.Type the Password. (Default is rav.)

4.Retype the password to confirm.

5.Click OK to save changes and close the window.

Note: This option is only available when you are

Figure 3.10. User name/Password

connected to a RAV unit.

 

To configure the Camera port

1.In the Serial tab, set the Baud Rate to match the baud rate indicated in the camera specifications.

2.Select Flow Control to enable hardware flow control.

3.Click OK to save settings and close the window.

To configure the Control port

1.

Set the Control Port Baud Rate to match the baud

 

 

rate of the PC COM port or the control device.

Figure 3.11. Serial settings

2.

Select Flow Control to enable hardware flow

 

 

control. (Flow Control is selected as default.)

 

3.

Click OK to save settings and close the window.

 

To configure the Camera port Note: Flow Control is the regulation of information between two devices that are connected to one another. ClearOne recommends enabling Flow Control on the RAV system.

Attention: If you are connected to the RAV unit through the serial port, you will need to reboot ! the unit before the baud rate and flow control changes take place. If you are connected to the

RAV unit through the USB port, changes are made instantly.

To change RF frequency channel

1.In the Frequency tab, select a frequency.

2.Click OK to save settings and close the window

Note: The channel frequency allows the mixer to communicate with the controller. The frequency used by RAV-Ware must match the frequency used by the controller. See page 58 to set the controller frequency.

!Attention: If you are using the European or South African version of RAV Frequency 1 and Frequency 8 are the same frequency.

Figure 3.12. Frequency settings

RAV-Ware— Configuring System Settings

 

33

 

Regional Settings

In the Regional Settings window, you can configure the date and time to ensure an accurate time stamp on log files.

To open Regional Settings

Click the Regional Settings icon in the Configuration screen.

To set date and time

1.Select Use Local Time if you want to use the time on your local computer.

– Or –

Clear the Use Local Time checkbox and enter the IP address for the time server.

2.Select Use Daylight Savings if your region observes daylight savings time.

3.Select your Time Zone and click OK.

4.Click Yes to confirm changes.

Figure 3.13. Date/Time settings

Telephone Settings

In the Telephone Settings window you can set telephone preferences such as auto-answer, auto-disconnect, ringer melody and program the local number. You can also adjust the telco level control, country setting and the flash settings.

To open Telephone Settings

Click the Telephone Settings icon in the Configuration screen.