Assigning device ID numbers

Installation ~ Hardware Setup

Assigning device ID numbers

Once your physical G-Link network is established, you need to set up unique G-Link device ID numbers for each AP10 on the network. As shipped from the factory, all AP10 units default as binary address 0. Set device ID numbers for each AP10 unit at your site by manipulating front-panel DIP switches 9–12, selecting/deselecting each switch to set up address 0–15 in binary code. Use the table below to determine the proper DIP switch settings for the device ID you want to assign.

9

!assigned the same device ID number, the TransmitIf more than one AP10 is

and Receive LEDs will flash red and green on the affected units until the error is corrected.

Device ID DIP switch settings

Binary

DIP Switch 9

DIP Switch 10

DIP Switch 11

DIP Switch 12

 

Address

Position

Position

Position

Position

 

0

0

(DOWN)

0

(DOWN)

0

(DOWN)

0

(DOWN)

 

1

0

(DOWN)

0

(DOWN)

0

(DOWN)

1

(UP)

 

2

0

(DOWN)

0

(DOWN)

1

(UP)

0

(DOWN)

 

3

0

(DOWN)

0

(DOWN)

1

(UP)

1

(UP)

 

4

0

(DOWN)

1

(UP)

0

(DOWN)

0

(DOWN)

 

5

0

(DOWN)

1

(UP)

0

(DOWN)

1

(UP)

 

6

0

(DOWN)

1

(UP)

1

(UP)

0

(DOWN)

 

7

0

(DOWN)

1

(UP)

1

(UP)

1

(UP)

 

8

1

(UP)

0

(DOWN)

0

(DOWN)

0

(DOWN)

 

9

1

(UP)

0

(DOWN)

0

(DOWN)

1

(UP)

 

10 (A)

1

(UP)

0

(DOWN)

1

(UP)

0

(DOWN)

 

11 (B)

1

(UP)

0

(DOWN)

1

(UP)

1

(UP)

 

12 (C)

1

(UP)

1

(UP)

0

(DOWN)

0

(DOWN)

 

13 (D)

1

(UP)

1

(UP)

0

(DOWN)

1

(UP)

 

14 (E)

1 (UP)

1 (UP)

1 (UP)

0

(DOWN)

 

15 (F)

1 (UP)

1 (UP)

1 (UP)

1

(UP)

 

 

 

 

 

 

 

 

 

 

 

Connecting power

The power input [1] will operate at any level between 100–240VAC, 50–60Hz, 15W (typical). Plug in the AP10 to complete the hardware installation.