Operation ~ Controllers

17

To mute

Click Mute TX to mute the transmit audio (audio sent to the telephone line).

Click Mute RX to mute the receive audio (audio from the telephone line).

Other telco options

Hook-Flash.This button sends a momentary interruption in line seizure to the telephone line.

Re-Null.This feature sends a short noise burst down the telephone line and forces the AP10 to adapt to the telephone line.

Auto-Answer.This button turns auto-answer on and off. If auto-answer is turned on, the AP10 answers the call after the first complete ring. If it is turned off, you will need to manually answer the call. You must have DIP switch 4 in the on (up) position.

Controllers

Custom control through DB-25 port

A customer-supplied remote control or contact-closure switch can be programmed to perform functions such as: mute on/off, system on, and system off. For pinouts, see Remote connector pinout, page 20.

Touch panel control

The AP products are designed to function with touch panel control systems. The controller is connected to the AP800 RS-232 port. Through the G-Link network, all networked AP products can be accessed and controlled from that single point.

Using a touch panel, you can control the following: AP10 on or off control; transmit and receive audio mute; DTMF tone generation; volume control for receive audio; query of the AP10’s binary address; re-nulling the telephone hybrid; metering of input and output, and ERL and ERLE. These commands are also available in the AP-Ware software, which communicates with the AP10 via an AP800 RS-232 serial port and the G-Link network.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 21
Image 21
ClearOne comm AP10 To mute, Other telco options, Controllers, Custom control through DB-25 port, Touch panel control